Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Healthcare Informatics Research ; : 218-227, 2023.
Article in English | WPRIM | ID: wpr-1000443

ABSTRACT

Objectives@#Intraoperative navigation reduces the risk of major complications and increases the likelihood of optimal surgical outcomes. This paper presents an augmented reality (AR)-based simulation technique for ventriculostomy that visualizes brain deformations caused by the movements of a surgical instrument in a three-dimensional brain model. This is achieved by utilizing a position-based dynamics (PBD) physical deformation method on a preoperative brain image. @*Methods@#An infrared camera-based AR surgical environment aligns the real-world space with a virtual space and tracks the surgical instruments. For a realistic representation and reduced simulation computation load, a hybrid geometric model is employed, which combines a high-resolution mesh model and a multiresolution tetrahedron model. Collision handling is executed when a collision between the brain and surgical instrument is detected. Constraints are used to preserve the properties of the soft body and ensure stable deformation. @*Results@#The experiment was conducted once in a phantom environment and once in an actual surgical environment. The tasks of inserting the surgical instrument into the ventricle using only the navigation information presented through the smart glasses and verifying the drainage of cerebrospinal fluid were evaluated. These tasks were successfully completed, as indicated by the drainage, and the deformation simulation speed averaged 18.78 fps. @*Conclusions@#This experiment confirmed that the AR-based method for external ventricular drain surgery was beneficial to clinicians.

2.
Yonsei Medical Journal ; : 166-172, 2022.
Article in English | WPRIM | ID: wpr-919600

ABSTRACT

Purpose@#Globus pallidus pars interna (GPi) has become an established target for deep brain stimulation (DBS) in dystonia. Previous studies suggest that targeting the ventralis oralis (Vo) complex nucleus improves dystonic tremor or even focal dystonia. Research has also demonstrated that multi-target DBS shows some benefits over single target DBS. In this study, we reviewed patients who had undergone unilateral DBS targeting the GPi and Vo. @*Materials and Methods@#Five patients diagnosed with medically refractory upper extremity dystonia (focal or segmental) underwent DBS. Two DBS electrodes each were inserted unilaterally targeting the ipsilateral GPi and Vo. Clinical outcomes were evaluated using the Burke-Fahn-Marsden Dystonia Rating Scale (BFMDRS) and Disability Rating Scale. @*Results@#BFMDRS scores decreased by 55% at 1-month, 56% at 3-month, 59% at 6-month, and 64% at 12-month follow up. Disability Rating Scale scores decreased 41% at 1-month, 47% at 3-month, 50% at 6-month, and 60% at 12-month follow up. At 1 month after surgery, stimulating both targets improved clinical scores better than targeting GPi or Vo alone. @*Conclusion@#Unilateral thalamic and pallidal dual electrode DBS may be as effective or even superior to DBS of a single target for dystonia. Although the number of patients was small, our results reflected favorable clinical outcomes.

3.
Cancer Research and Treatment ; : 733-743, 2021.
Article in English | WPRIM | ID: wpr-897465

ABSTRACT

Purpose@#We aimed to develop a novel method for orthotopic colon cancer model, using tissue adhesive in place of conventional surgical method. @*Materials and Methods@#RFP HCT 116 cell line were used to establish the colon cancer model. Fresh tumor tissue harvested from a subcutaneous injection was grafted into twenty nude mice, divided into group A (suture method) and group B (tissue adhesive method). For the group A, we fixed the tissue on the serosa layer of proximal colon by 8-0 surgical suture. For the group B, tissue adhesive (10 μL) was used to fix the tumor. The mortality, tumor implantation success, tumor metastasis, primary tumor size, and operation time were compared between the two groups. Dissected tumor tissue was analyzed for the histology and immunohistochemistry. Also, we performed tumor marker analysis. @*Results@#We observed 30% increase in graft success and 20% decrease in mortality, by using tissue adhesive method, respectively. The median colon tumor size was significantly increased by 4 mm and operation time was shortened by 6.5 minutes. The H&E showed similar tumor structure between the two groups. The immunohistochemistry staining for cancer antigen 19-9, carcinoembryonic antigen, cytokeratin 20, and Ki-67 showed comparable intensities in both groups. Real-time quantitative reverse transcription analysis showed eight out of nine tumor markers are unchanged in the tissue adhesive group. Western blot indicated the tissue adhesive group expressed less p-JNK (apototic marker) and more p-MEK/p-p38 (proliferation marker) levels. @*Conclusion@#We concluded the tissue adhesive method is a quick and safe way to generate orthotopic, colon cancer model.

4.
Cancer Research and Treatment ; : 733-743, 2021.
Article in English | WPRIM | ID: wpr-889761

ABSTRACT

Purpose@#We aimed to develop a novel method for orthotopic colon cancer model, using tissue adhesive in place of conventional surgical method. @*Materials and Methods@#RFP HCT 116 cell line were used to establish the colon cancer model. Fresh tumor tissue harvested from a subcutaneous injection was grafted into twenty nude mice, divided into group A (suture method) and group B (tissue adhesive method). For the group A, we fixed the tissue on the serosa layer of proximal colon by 8-0 surgical suture. For the group B, tissue adhesive (10 μL) was used to fix the tumor. The mortality, tumor implantation success, tumor metastasis, primary tumor size, and operation time were compared between the two groups. Dissected tumor tissue was analyzed for the histology and immunohistochemistry. Also, we performed tumor marker analysis. @*Results@#We observed 30% increase in graft success and 20% decrease in mortality, by using tissue adhesive method, respectively. The median colon tumor size was significantly increased by 4 mm and operation time was shortened by 6.5 minutes. The H&E showed similar tumor structure between the two groups. The immunohistochemistry staining for cancer antigen 19-9, carcinoembryonic antigen, cytokeratin 20, and Ki-67 showed comparable intensities in both groups. Real-time quantitative reverse transcription analysis showed eight out of nine tumor markers are unchanged in the tissue adhesive group. Western blot indicated the tissue adhesive group expressed less p-JNK (apototic marker) and more p-MEK/p-p38 (proliferation marker) levels. @*Conclusion@#We concluded the tissue adhesive method is a quick and safe way to generate orthotopic, colon cancer model.

5.
Obstetrics & Gynecology Science ; : 136-143, 2014.
Article in English | WPRIM | ID: wpr-228429

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate risk factors of vaginal cuff dehiscence or evisceration according to the type of operation. METHODS: Medical records of 604 women who underwent hysterectomies at Korea University Anam Hospital between June 2007 and June 2011 were reviewed. They were allocated to six groups. The six types of hysterectomies included robotic hysterectomy (n = 7), robotic radical hysterectomy and node dissection (RRHND, n = 9), total laparoscopic hysterectomy (TLH, n = 274), laparoscopy assisted vaginal hysterectomy (LAVH, n = 238), laparoscopic radical hysterectomy and node dissection (n = 11), and abdominal radical hysterectomy (ARH, n = 63). The characteristics and outcomes of each groups were compared. RESULTS: There was no difference in the characteristics of patients between 6 groups. In total of 604 hysterectomies, 3 evisceration (0.49%) and 21 dehiscences (3.47%) occurred. Evisceration were found in RRHND (1/9, 11.1%), TLH (1/276, 0.36%), and ARH (1/63, 1.56%). Dehiscences occurred in TLH (15/274, 5.42%), LAVH (4/238, 1.68%), and ARH (2/63, 3.17%). In 169 cases of TLH with intra-corporeal continuous suture, 1 evisceration and 4 dehiscences occurred, whereas 11 dehiscences occurred in 105 TLH cases with vaginal continuous locking suture (2.96% vs. 10.47%, P = 0.02). CONCLUSION: The incidence of vaginal cuff dehiscenceand eviscerationwas significantly higher in TLH than LAVH. The intra-corporeal cuff suture was superior to the vaginal suture to prevent the vaginal cuff complications in TLH.


Subject(s)
Female , Humans , Hysterectomy , Hysterectomy, Vaginal , Incidence , Korea , Laparoscopy , Medical Records , Risk Factors , Surgical Wound Dehiscence , Suture Techniques , Sutures
SELECTION OF CITATIONS
SEARCH DETAIL